Search results for "Multifocal IOL"

showing 10 items of 10 documents

Accuracy of five intraocular lens formulas in eyes with trifocal lens implant.

2020

Accuracy of intraocular lens (IOL) calculation formulas SRK/T, Hoffer Q, Holladay 1, Haigis and Barrett Universal II were compared in prediction of postoperative refraction for multifocal and implants using a single optical biometry device. The authors included 88 refractive lens exchange and cataract surgeries, with AcrySof IQ PanOptix implant (Alcon Laboratories, Inc.). All eyes were divided into three groups based on axial length (AL), group 1: 24.5 mm (6 eyes). The refractive prediction error (RPE) and mean absolute error (MAE) were calculated for 5 different formulas: SRK/T, Hoffer Q, Holladay 1, Haigis and Barrett Universal II. For eyes with the AL between 22 mm and 24.5 mm the greate…

0301 basic medicineCancer Researchmedicine.medical_specialtymultifocalmedicine.medical_treatmentStatistical differenceIntraocular lens03 medical and health sciences0302 clinical medicineOptical biometryImmunology and Microbiology (miscellaneous)OphthalmologymedicinehydrophobictrifocalMathematicsPanOptixLens implantAnova testArticlesintraocular lens formulasGeneral MedicinePresbyopiamedicine.diseaseAlcon Laboratories030104 developmental biology030220 oncology & carcinogenesispresbyopiaMultifocal IOLsoptical biometryExperimental and therapeutic medicine
researchProduct

Working-Age Cataract Patients: Visual Results, Reading Performance, and Quality of Life with Three Diffractive Multifocal Intraocular Lenses

2013

Purpose To compare the visual outcomes, reading performance, and quality of life (QoL) of working-age cataractous patients bilaterally implanted with 3 different diffractive multifocal intraocular lenses (MIOLs). Design Two-center, randomized, prospective, double-masked study. Participants Sixty-three consecutive patients (126 eyes) seen at Ophthalmology Section, Palermo and Florence University, Italy, randomized to receive the ReSTOR SN6AD3 (Alcon Laboratories, Inc, Irvine, CA) (20 patients, group A), ReSTOR SN6AD1 (Alcon Laboratories, Inc) (21 patients, group B), or TECNIS ZMA00 (Abbott Medical Optics, Santa Ana, CA) (22 patients, group C) MIOL. Intervention Phacoemulsification. Main Outc…

MaleRefractive errorVisual acuitygenetic structuresMesopic visionmedicine.medical_treatmentMesopic VisionVisual AcuitySettore MED/42 - Igiene Generale E ApplicataLens Implantation IntraocularSickness Impact ProfileSurveys and QuestionnairesMedicineContrast (vision)Prospective StudiesProspective cohort studyOPTICAL-QUALITYmedia_commonLenses IntraocularVision BinocularOUTCOMESMiddle AgedRESTORFemalemedicine.symptomA+3.00 DPhotopic visionDIOPTER ADDITIONmedicine.medical_specialtyINSTITUTE-REFRACTIVE ERRORmedia_common.quotation_subjectMODELSProsthesis DesignCataractDouble-Blind MethodOphthalmologyCONTRAST SENSITIVITYHumansBILATERAL IMPLANTATIONPhacoemulsificationColor Visionbusiness.industrySettore MED/30 - Malattie Apparato VisivoPhacoemulsificationMultifocal intraocular lensmedicine.diseaseeye diseasesOphthalmologyVISIONINSTITUTE-REFRACTIVE ERROR; CONTRAST SENSITIVITY; BILATERAL IMPLANTATION; DIOPTER ADDITION; OPTICAL-QUALITY; A+3.00 D; VISION; RESTOR; OUTCOMES; MODELSReadingQuality of LifeOptometryMultifocal IOL diffractive Quality of lifebusinessFollow-Up Studies
researchProduct

Bilateral implantation of the Acri.LISA bifocal intraocular lens in myopic eyes.

2009

Purpose To asses visual quality after bilateral implantation of the Acri.LISA 366D intraocular lens (IOL) (Carl Zeiss Meditec) in patients with high and low–moderate myopia. Methods A total of 304 eyes of 152 patients had bilateral implantation of the Acri.LISA 366D IOL. The patients were divided into 2 groups: low–moderate myopia (IOL power from 15 to 20.5 D) and high myopia (IOL power from 0 to 14.5 D). Monocular and binocular best-corrected distance visual acuity (BCVA) and best distance-corrected near visual acuity (BCNVA), binocular best distance-corrected intermediate visual acuity (BCIVA), and distance contrast sensitivity (OS) under photopic (85 cd/m2) and mesopic (5 cd/m2) conditio…

MaleVisual acuitygenetic structuresMesopic visionmedicine.medical_treatmentVisual AcuityIntraocular lensExtractionFunctional LateralityTratamiento médico0302 clinical medicineLens Implantation IntraocularMyopiaContrast (vision)MedicineRetinal-Detachmentmedia_commonVistaLenses IntraocularVision BinocularDistanceHigh myopiaRetinal detachmentGeneral MedicineMiddle AgedQualityTreatment OutcomeOftalmologíaFemalemedicine.symptomPhotopic visionRiskmedia_common.quotation_subjectProsthesis DesignContrast Sensitivity03 medical and health sciencesHumansMonocularPhacoemulsificationbusiness.industryMultifocal Iolmedicine.diseaseeye diseasesVisual PerformanceOphthalmology030221 ophthalmology & optometryOptometrysense organsbusiness030217 neurology & neurosurgeryEuropean journal of ophthalmology
researchProduct

One-Year Outcomes with New-Generation Multifocal Intraocular Lenses

2007

Purpose: To compare new-generation multifocal intraocular lenses (IOLs) with monofocal IOLs. Design: Randomized prospective clinical trial. Participants: Sixty-two consecutive patients with cataract, seen between January of 2005 and January of 2006 at the Department of Ophthalmology of Palermo University Hospital in Italy, were bilaterally implanted with monofocal (AR 40, Advanced Medical Optics [AMO], Santa Ana, CA; 15 patients), multifocal refractive (Array SA40N, AMO; 16 patients), multifocal refractive (ReZoom, AMO; 15 patients), or multifocal diffractive pupil-independent (Tecnis ZM900, AMO; 16 patients) IOLs. Intervention: Bimanual phacoemulsification. Main Outcome Measures: Primary o…

Malemedicine.medical_specialtygenetic structuresmedicine.medical_treatmentmedia_common.quotation_subjectVisual AcuityIntraocular lensProsthesis DesignGlareContrast SensitivityLens Implantation IntraocularSurveys and QuestionnairesOphthalmologylente refrattiva chirurgia della catarattaHumansMedicineContrast (vision)Prospective StudiesDioptreAgedmedia_commonLenses IntraocularDepth PerceptionPhacoemulsificationSettore MED/30 - Malattie Apparato Visivobusiness.industryLe lenti multifocali intraoculari di nuova generazioneGlare (vision)PhacoemulsificationMiddle AgedMultifocal intraocular lensUniversity hospitaleye diseasesOphthalmologyTreatment Outcomelente diffrattivaPatient SatisfactionQuality of LifeOptometryMultifocal IOLsFemalesense organsbusinessOphthalmology
researchProduct

IOL Multifocali di II e III generazione: performance visiva e capacità di lettura

2011

Multifocal IOL reading speed contrast sensitivity
researchProduct

Comfort visivo e indipendenza da occhiali con IOLs multifocali di nuova generazione: follow-up a 1 anno

2008

Multifocal IOLs presbyopia cataract
researchProduct

Evaluation of the performance of multifocal intraocular lenses image quality: analysis of the standard methods

2007

Purpose: To analyze the standard methods used to describe intraocular lenses (IOL) and to suggest some improvements to make them applicable for multifocal IOLs. Methods: The EN-ISO standards and the standards of the American National Standards Institute (ANSI) for the evaluation of the performance of IOLs are tested for multifocal IOLs. The MTF of the one refractive multifocal IOL and two hybrid refractive-diffractive multifocal IOLs is measured for both distance focus and near focus and using different pupil sizes. Results: The average modulation (AM) from 0 to 100 c/mm of multifocal IOLs (for the distance focus) is about 40-50% lower than the AM of monofocal IOLs, for all pupil sizes stud…

Point spread functionbusiness.industryPupil sizeMultifocal intraocular lensStandard methodsPupilOphthalmologyOpticsImage quality analysisIntraocular lensesOptometryMultifocal IOLsMedicinebusinessActa Ophthalmologica Scandinavica
researchProduct

ACUITA’ VISIVA, PERFORMANCE DI LETTURA, QUALITA’ DELLA VITA E SENSIBILITA’ AL CONTRASTO SOGGETTIVA ED ELETTROFUNZIONALE IN PAZIENTI AFFETTI DA CATARA…

Settore MED/30 - Malattie Apparato VisivoMultifocal IOLs VEPs presbyopia contrast sensitivity
researchProduct

Multifokale Intraokularlinsen

2001

Modern cataract surgery has developed tremendously during the past 10-15 years. Improved surgical techniques, as well as improved implant materials and designs, have enlarged patient profiles and indications for cataract surgery. This also created much higher expectations from the patients' site. The loss of accommodation is loss of quality of life for presbyopic and especially young pseudophakic patients. Therefore cataract surgery with multifocal IOL implantation is not only of academic interest, but reflects demands and expectations of our patients. Multifocal IOLs have been implanted since 1986, starting with 2-3 zone refractive and diffractive designs. Due to surgical techniques of tha…

genetic structuresmedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentEye diseaseGlare (vision)Intraocular lensCataract surgeryCorneal topographymedicine.diseaseAphakiaeye diseasesOphthalmologymedicineOptometryMultifocal IOLssense organsImplantbusinessDer Ophthalmologe
researchProduct

Visual Performance after AcrySof ReSTOR Aspheric Intraocular Lens Implantation

2008

Purpose: To evaluate distance, intermediate and near visual performance in patients who had undergone implantation of the multifocal aspheric AcrySof ReSTOR intraocular lens (IOL). Methods: Binocular best distance corrected visual acuity (BCVA) at high and low contrast [4 m], best distance corrected near visual acuity (BCNVA) [40 cm], intermediate visual acuity [80 and 60 cm], and distance contrast sensitivity (CS) under photopic [85 cd/m2] and mesopic [3 cd/m2] conditions, were measured in 36 eyes that underwent implantation of the AcrySof ReSTOR Aspheric IOL (SN6AD3). Results: At the 3-month postoperative visit, binocular BCVA was -0.058±0.091, 0.200±0.079, and 0.258±0.071 logMAR, for 100…

medicine.medical_specialtygenetic structuresmedicine.medical_treatmentdiffractionLIO multifocalIntraocular lenslcsh:OphthalmologyOphthalmologymedicinemultifocal IOLvisual functionlcsh:QC350-467In patientasfericidaddifracciónbusiness.industryfunción visualeye diseasesasphericityVisual functionlcsh:RE1-994OptometryOriginal Articlesense organsbusinesslcsh:Optics. LightOptometryJournal of Optometry
researchProduct